PR 500 |
PR 520 |
PR 300 |
EPHB CR |
WB Primer |
ESD PR 1 |
ESD PR 2 |
%Solids (By Volume)
As Supplied
|
100* |
100* |
100* |
100* |
31 |
54 |
100 |
Impact Resistance
ASTM D 2794 Gardner
|
N/A |
N/A |
160 in.-lbs
(180 cm-kg)
direct & reverse
|
40 in.-lbs
(44.8 cm-kg)
direct & reverse |
80 in.-lbs
(89.6 cm-kg)
direct & reverse |
160 in.-lbs
(180 cm-kg)
direct & reverse |
160 in.-lbs
(180 cm-kg)
direct & reverse |
Flexibility
ASTM D 522 Conical Mandrel
|
1/8 in.
(.31 cm)
passes |
1/8 in.
(.31 cm)
passes |
1/8 in.
(.31 cm)
passes |
1/4 in.
(.62 cm)
passes |
1/8 in.
(.31 cm)
passes |
1/8 in.
(.31 cm)
passes |
1/8 in.
(.31 cm)
passes |
Hardness
ASTM D 3363 Pencil
|
2B |
2B |
2B |
2B |
2B |
2B |
2B |
Adhesion: Concrete ASTM D 4541 Elcometer |
350 psi
(2.4 MPA)
concrete
failure |
350 psi
(2.4 MPA)
concrete
failure |
for use on tile |
350 psi
(2.4 MPA)
concrete
failure |
350 psi
(2.4 MPA)
concrete
failure |
350 psi
(2.4 MPA)
concrete
failure |
350 psi
(2.4 MPA)
concrete
failure |
|
|
|
|
|
|
|
|